Uri: Solenoid Valve Bank, Uri ng Fluid: Air, Inert Gas,
Uri: Vacuum Generator, Pag-andar: Pressure Operated, Pagpipilit ng Operasyon: 30 ~ 116PSI (2 ~ 8 bar), Uri ng Fluid: Air, Inert Gas,
Uri: Sub-Base, End,
Uri: Amplifier Relay, Pag-andar: Positive Output, Pagpipilit ng Operasyon: 7 ~ 36PSI (0.5 ~ 2.5 bar), Uri ng Fluid: Air, Inert Gas,
Uri: Logic Element, Pag-andar: LOGIC OR, Pagpipilit ng Operasyon: 30 ~ 116PSI (2 ~ 8 bar), Orifice Diameter: 0.106" (2.70mm), Uri ng Fluid: Air, Inert Gas,
Uri: Solenoid Valve, Pag-andar: 3/2 Normally Closed, Pagpipilit ng Operasyon: 15 ~ 116PSI (1 ~ 8 bar), Orifice Diameter: 0.032" (0.80mm), Uri ng Fluid: Air, Inert Gas,
Uri: Position Detector, Pag-andar: 3/2 Normally Closed, Uri ng Actuator: Lever, Roller, Pagpipilit ng Operasyon: 1 ~ 116PSI (0.1 ~ 8 bar), Orifice Diameter: 0.106" (2.70mm), Uri ng Fluid: Air, Inert Gas,
Uri: Pressure Switch, Pag-andar: Positive Output, Pagpipilit ng Operasyon: 0.7 ~ 7PSI (0.05 ~ 0.5 bar), Orifice Diameter: 0.098" (2.50mm), Uri ng Fluid: Air, Inert Gas,
Uri: Control Valve, Momentary, Pag-andar: 3/2 Normally Closed, Uri ng Actuator: Pushbutton, Pagpipilit ng Operasyon: 30 ~ 116PSI (2 ~ 8 bar), Orifice Diameter: 0.106" (2.70mm), Uri ng Fluid: Air, Inert Gas,
Uri: Impulse Generator, Fixed, Pagpipilit ng Operasyon: 30 ~ 116PSI (2 ~ 8 bar), Orifice Diameter: 0.106" (2.70mm), Uri ng Fluid: Air, Inert Gas,
Uri: Logic Element, Pag-andar: LOGIC AND, Pagpipilit ng Operasyon: 30 ~ 116PSI (2 ~ 8 bar), Orifice Diameter: 0.157" (4.00mm), Uri ng Fluid: Air, Inert Gas,
Uri: Control Valve, Momentary, Pag-andar: 3/2 Normally Closed, Uri ng Actuator: Paddle, Pagpipilit ng Operasyon: 30 ~ 116PSI (2 ~ 8 bar), Orifice Diameter: 0.106" (2.70mm), Uri ng Fluid: Air, Inert Gas,
Uri: Solenoid Valve, Pag-andar: 3/2 Normally Closed, Pagpipilit ng Operasyon: 15 ~ 116PSI (1 ~ 8 bar), Orifice Diameter: 0.020" (0.50mm), Uri ng Fluid: Air, Inert Gas,
Uri: Pressure Switch, Pag-andar: Pressure Operated, Pagpipilit ng Operasyon: 30 ~ 116PSI (2 ~ 8 bar), Uri ng Fluid: Air, Inert Gas, Liquid,
Uri: Sub-Base,
Uri: Timer, Adjustable, Pag-andar: On-Delay, Pagpipilit ng Operasyon: 30 ~ 116PSI (2 ~ 8 bar), Orifice Diameter: 0.106" (2.70mm), Uri ng Fluid: Air, Inert Gas,
Uri: Timer, Fixed, Pag-andar: On-Delay, Pagpipilit ng Operasyon: 30 ~ 116PSI (2 ~ 8 bar), Orifice Diameter: 0.106" (2.70mm), Uri ng Fluid: Air, Inert Gas,
Uri: Position Detector, Pag-andar: 3/2 Normally Closed, Uri ng Actuator: Side Rotary - No Lever, Pagpipilit ng Operasyon: 1 ~ 116PSI (0.1 ~ 8 bar), Orifice Diameter: 0.118" (3.00mm), Uri ng Fluid: Air, Inert Gas,
Uri: Control Relay, Pag-andar: 2-Hand Start, Uri ng Actuator: Pushbutton, Dual, Pagpipilit ng Operasyon: 30 ~ 116PSI (2 ~ 8 bar), Orifice Diameter: 0.098" (2.50mm), Uri ng Fluid: Air, Inert Gas,
Uri: Pressure Switch, Pag-andar: Positive Output, Pagpipilit ng Operasyon: 1 ~ 36PSI (0.1 ~ 2.5 bar), Orifice Diameter: 0.098" (2.50mm), Uri ng Fluid: Air, Inert Gas,
Uri: Pressure Switch, Pag-andar: Negative Output, Pagpipilit ng Operasyon: 0.7 ~ 7PSI (0.05 ~ 0.5 bar), Orifice Diameter: 0.098" (2.50mm), Uri ng Fluid: Air, Inert Gas,
Uri: Sub-Base, Intermediate,
Uri: Flow Restrictor, Adjustable, Pag-andar: One-Way, Pagpipilit ng Operasyon: 15 ~ 116PSI (1 ~ 8 bar), Orifice Diameter: 0.020" (0.50mm), Uri ng Fluid: Air, Inert Gas,
Uri: Position Detector, Pag-andar: 3/2 Normally Open, Uri ng Actuator: Round (Pin Plunger), Pagpipilit ng Operasyon: 30 ~ 116PSI (2 ~ 8 bar), Orifice Diameter: 0.106" (2.70mm), Uri ng Fluid: Air, Inert Gas,
Uri: Sub-Base, Pagpipilit ng Operasyon: 30 ~ 116PSI (2 ~ 8 bar),